Measuring range | 1...150cm/s(water),3...300cm/s(oil),20...2000cm/s(gas) |
Output signal | PNP,NPN,Relay |
Power supply | 24V±20%DC |
Pull-in current | Max/400mA(PNP or NPN);max1A@24V ac/dc(Relay) |
No-load current | Max/80mA |
Flow indicator | LED row/six |
Set | Potentiometer setting |
Anti-pressure range | 100bar |
Response time | 1-13s,typical/2s |
Initialization time | About 8s |
Protection grade | IP67 |
Medium temperature | -20-80℃ |
Ambient temperature | -20-80℃ |
Storage temperature | -20-100℃ |
Wiring mode | M12 plug-in |
Material | Probe/SS,housing/SS |
Weight | About 0.4kg |