400 662 6286
Range : | -100KPA-0,0-0.6MPA ,0-10MPA ,0-100MPA 0-200MPA(the range can be discussed) |
Comprehensive precision: | 0.1%FS(code name:S),0.25%FS(code name:A);0.5%FS (code name:B); |
Nonlinear value: | 0.2% of the full range |
Reliability value: | 0.05% of the full range |
Output signal: | 4-20mA(two-wire code:2); 0-10V(code:3);0-5V(three-wire code:4) 4-20mA+HART(code:5);RS485(code:6) |
Supply voltage: | 24(12~36)VDC (amplifying signal) |
Temperature range: | -20~180℃ |
Compensation temperature: | 0~65℃ |
Overload pressure: | 1.5times of the rated pressure |
Response time: | ≤1ms(up to 90%FS) |
Body materials: | Wetted material:316L,shell material:stainless steel, hard aluminum |
Electrical connection: | (code name:D1)Hersman(DIN43650),enclosure protection:IP65;waterproof gland,enclosure protectionIP68(code name:D2);Aviation plug-in,enclosure plug-inIP45(code name:D3); |
Pressure connection: | G1/4, G1/2, 1/2NPT, 1/4NPT, M12*1.5,etc.(customization) |
Product model | Range | Accuracy | Output signal | Screw connection | Electrical connection |
MX-YL-02 | 50BAR | 0.25 | 4-20MA | M20*1.5 | Hersman |
E g: MX-YL-02-50Bar-A2-G1/2-D1 |