Measuring range: | -100KPA-0,0-0.6MPA ,0-10MPA ,0-100MPA(the range can be discussed) |
Comprehensive precision: | 0.25%FS(code name:A);0.5%FS (code name:B); |
Nonlinear value: | 0.2% of the full range |
Reliability value: | 0.05% of the full range |
Output signal: | 4-20mA(two-wire code:2);0-10V(code:3);0-5V(three-wire code:4) 4-20mA+HART(code:5);RS485(code:6) |
Supply voltage: | 24(12~36)VDC (amplifying signal) |
Operation temperature: | -20~80℃ special custom-made is needed when the temperature surpass 80 |
Compensation temperature: | 0~65℃ |
Overload pressure: | 1.5 times of the rated pressure |
Response time: | ≤1ms(up to 90%FS) |
Body material: | wetted material:316L,the enclosure is made of stainless steel and hard aluminum |
Electrical connection: | (code name:D1)Hersman(DIN43650),enclosure protectionIP65;waterproof gland,enclosure protectionIP68(code name:D2);Aviation plug-in,enclosure protectionIP45(code name:D3); |
Pressure connection: | G1/2, 1/2NPT,M20,M22,etc(customization ) |
Type | Range | Accuracy | Output signal | Screw connector | Electrical connection | Other requirements |
MX-YL-11 | 50BAR | 0.25 | 4-20MA | G1/2 | Hersman | --- |
E g: MX-YL-11-50Bar-A2-G1/2-D1 |