Electromagnetic Flowmeter MX-LL-116-01
MX - LL - 116-01 series Electromagnetic flowmeter (Electromagnetic Flowmeters, EMF) : according to Faraday's law of Electromagnetic induction (Faraday's law of Electromagnetic induction: when the conductor in magnetic field cutting lines of magnetic force exercise, on both ends of a conductor will be induced a conductor and magnetic field direction and movement direction perpendicular induced electromotive force) tested flow meter.The advantages of electromagnetic flowmeter are that the pressure loss is very small and the measured flow range is large.The ratio of maximum flow rate to minimum flow rate is generally above 20:1, the applicable industrial pipe diameter range is wide, up to 3m, the output signal and measured flow rate are linear, the accuracy is high, can measure the conductivity ≥5 s/cm acid, alkali salt solution, water, sewage, corrosive liquid.


Tel:

400 662 6286

1.Product description:   

         MX - LL - 116-01 series Electromagnetic flowmeter (Electromagnetic Flowmeters, EMF) : according to Faraday's law of Electromagnetic induction (Faraday's law of Electromagnetic induction: when the conductor in magnetic field cutting lines of magnetic force exercise, on both ends of a conductor will be induced a conductor and magnetic field direction and movement direction perpendicular induced electromotive force) tested flow meter.The advantages of electromagnetic flowmeter are that the pressure loss is very small and the measured flow range is large.The ratio of maximum flow rate to minimum flow rate is generally above 20:1, the applicable industrial pipe diameter range is wide, up to 3m, the output signal and measured flow rate are linear, the accuracy is high, can measure the conductivity ≥5 s/cm acid, alkali salt solution, water, sewage, corrosive liquid.
 
OK
2.Applying field:
1. Petrochemical industry, iron and steel metallurgy
2. Water supply and drainage, water conservancy irrigation
3. Water treatment, sewage treatment station
4. Mud, pulp, etc
5. Distillation and denitration engineering
6. Paper-making (pulp), mud, medicine, food,etc.

3.Product feathers

1. Fluid density, viscosity, temperature, pressure and conductivity changes, the influence of the linear principle to achieve high precision measurement
2. Unimpeded flow measuring tube and the moving parts, the pressure loss is small, so not cause additional energy loss
3. High-definition backlit LCD display, full Chinese menu operation, easy to use, simple operation, easy to understand
4. With functions of conductivity measurement, it can be judged whether flowmeter atc, has self-check and diagnostic function
5. Internal calculators showed positive cumulative flow respectively, reverse flow and transient flow
6. Plug-in electromagnetic flowmeter, simple installation, can not stop the scene with the open hole, with the installation of absolute advantage and price advantage
7. Low installation requirements, behind the front straight pipe is greater than 5 D, straight pipe length is greater than 3 D can be for instrument internal diameter (D)

4.Type-caliber specification:

The choice of the diameter of the electromagnetic flowmeter depends on the diameter of the pipeline to be measured and the velocity of the measured medium. Please refer to the aperture selection table to try to make the common flow rate of the measured medium in the yellow font area of the table.
 

Caliber:DN Corresponding scale flow(m3/h)
(mm)
V(m/s) 0.57 0.68 0.9 1.1 1.4 1.7 2.3 2.8 3.4 4.5 5.7 6.8 9.1  
25 1 1.2 1.6 2 2.5 3 4 5 6 8 10 12 16  
32 1.6 2 2.5 3 4 5 6 8 10 12 16 20 25  
40 2.5 3 4 5 6 8 10 12 16 20 25 30 40  
50 4 5 6 8 10 12 16 20 25 30 40 50 60  
65 6 8 10 12 16 20 25 30 40 50 60 80 100 120
80 10 12 16 20 25 30 40 50 60 80 100 120 160  
100 16 20 25 30 40 50 60 80 100 120 160 200 250  
125 25 30 40 50 60 80 100 120 160 200 250 300 400  
150 40 50 60 80 100 120 160 200 250 300 400 500 600  
200 60 80 100 120 160 200 250 300 400 500 600 800 1000  
250 100 120 160 200 250 300 400 500 600 800 1000 1200    
300 160 200 250 300 400 500 600 800 1000 1200 1600 2000    
400 250 300 400 500 600 800 1000 1200 1600 2000 2500 3000    
450 300 400 500 600 800 1000 1200 1600 2000 2500 3000      
 
Note: 1. The flow/velocity data in the table are approximate values, and the yellow area is the recommended flow meter to measure the flow/velocity.
2. Flow rate conversion formula: flow rate v=354× flow rate q/D
In the equation: q-m /h, V-m /s, D(DN) -mm

5.Selection description-Electrode materials:

Material Corrosion resistance performance
Stainless steel:316L Application: 1. Domestic water, industrial water, raw water, well water, urban sewage
2. Mildly corrosive acid, alkali and salt solution
 
(HB) Application: 1. Non-oxidizing acids, such as hydrochloric acid (concentration less than 10%), etc
2. Alkali (partial) such as sodium hydroxide (concentration less than 50%), ammonium hydroxide base solution at all concentrations
3. Acid (partial), such as phosphoric acid, organic acid is not applicable: nitric acid
 
(HC) Application: 1. Mixed acid, such as chromic acid and sulfuric acid mixed solution
2. Oxidizing salts, such as Fe, Cu and seawater are not applicable: hydrochloric acid
 
(Ti) Application:1.Salt(partial), e.g. (1) chloride (chloride/Mg/Al/Ca/ammonia/Fe, etc.)
(2) Sodium salt, potassium salt, ammonium salt, hypochlorite, sea water
2. Alkali (partial), e.g. solution of potassium hydroxide, ammonium hydroxide and barium hydroxide whose concentration is less than 50%
Not applicable: hydrochloric acid, sulfuric acid, phosphoric acid, hydrofluoric acid and other reducing acids
 
(Ta) 1. Strong acids, such as hydrochloric acid (less than 40%), dilute and concentrated sulfuric acid (excluding fuming sulfuric acid)
2. Chlorine dioxide, ferric chloride, hypochlorous acid, sodium cyanide, lead acetate, etc
3. Oxidizing acids, such as nitric acid (including fuming nitric acid), etc., aqua regia below 80℃
Not applicable: alkali, hydrofluoric acid
 
(Pt) Application: Almost all acid, alkali, salt solution (including fuming sulfuric acid, fuming nitric acid)
Not applicable: Aqua aqua, Ammonium salt
 
 

6.Selection instructions - Earthing ring:1. The grounding ring is used to ground the measured medium and improve the stability of electromagnetic flowmeter measurement.However, the grounding ring needs to be in contact with the measured medium, and there is the possibility of corrosion and wear. After a period of use, it needs to be replaced.2.Shanghai Meixu measurement and control electromagnetic flowmeter generally USES grounding electrode instead of grounding ring, which has achieved good grounding effect and increased the convenience and reliability of use.3. Some small diameter electromagnetic flowmeters only have 2 electrodes, so users need to equip with a double ground ring.

The earthing ring should be installed in the exact pipe position so as not to affect the flow field of the measured medium
The measurement accuracy of electromagnetic flow depends on the grounding effect of the sensor
 

7.Technique specifications:

Model specification: CY-LL-116-01Y(one-piece); CY-LL-116-01F(split type);CY-LL-116-01D(power supply)
Nominal diameter: DN10、15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、500、600、700、800、900、1000、1200、1400、1600、1800、2000、2200、2400、2600、2800、DN3000   
Max velocity: 10M/S                                                      
Velocity resolution: 1MM/S                                                     
Installation: flange install(B1);thread install(B2);clamp install(B3)            
Precision : ±0.5%(code name A1),±1%(code name A2)                                                                                   
Inner material: Neoprene CR(code name C1);urethanesPU(code name C2);teflon F4 or PTFE(code name C3);teflon FEP(code name C4);copolymer(code name C5)             
Medium conductivity: greater than 30uS/cm                                    
Electrode material: 316L electrode(code name D1);Ti-electrode(code name D2);HB alloy(code name D3);HC electrode(code name D4);Ta-electrode(code name D5);Pb electrode(code name D6)           
Shell material: carbon steel shell(code name F1),304 stainless steel shell(code name F2);316 stainless steel shell (code name F3)
shell material:carbon steel     
Pressure class: P1:40kg=4MPA(DN10-DN150);P2:16kg=1.6MPA(DN15-DN150);P3:10kg=1MPA(DN200-DN600);P4:6kg=0.6MPA(DN700-DN2000)                  
Medium tem: +80℃or+120℃ or 200°C is optional,W1-level≤80°C(C1 and C2);W2-level≤120°C (C3 and C4); W3-level≤200°C (C5)                                                                                                                                        
Power supply mode: 220VAC alternating current(code name E1);24VDC direct current(code name E2);Lithium power supply-only for low power consumption(code name E3)                                           
Signal output: S1=4-20MA+RS458(standard);S2=4-20MA+HART;  defaulted 4-20MA+RS485(standard version)
Environment tem: -20~60℃
Wiring form: explosion-proof shell with digital display
Reference signal: 4-20mA、HART、pulse/frequency(0-5KHz),                     
Digital communications: digital communication:RS-485,supporting MODBUS-RTU Protocol;HART Protocol;GPRS

8.Selection guidance:

Type Path Precision Lining material Electrode material Shell material Pressure Tem Power supply Output
MX-LL-116-01Y DN50 0.5% Teflon 316L electrode Carbon steel 16kg 0-80° 24VDC 4-20MA
E g MX-LL-116-01Y-DN50-A1-C3-D1-F1-P2-W1-E2-S1