400 662 6286
Model description: | MX-WD-06 |
Tem-measuring component: | N,R,K,E,J,T,PT100,CU50 defaulted PT100 |
Precision level: | A level:+/- (0.15+0.2%t) ; B level:+/-(0.3+0.5%t) |
Tem range: | -200℃~150℃~1600℃ |
Output signal: | 4-20mA(two-wire code 2);4-20mA+HART(code 3) ;RS485(code 4) |
Process connection: | Screw install;clamp(50.5MM),clamp(63.5MM);flange install |
Power supply: | 24(12~36)VDC (amplified signal) |
Insert depth: | 50mm~3500mm,screw part is not include in the insert depth |
Dial head form: | Explosion-proof LCD digital display dial shell |
Protection pipe diameter: | 6mm;8mm;12mm;16mm |
Rod material: | 304(30A)316L(30B);Ti(30C);Teflon(30D)。 |
Type | Precision/signal | Range | Installation form | Insert depth and diameter | Protection pipe material |
MX-WD-06 | 0.2%/4-20MA | -20-150° | M27 | 100/6 | 304 |
E g: | MX-WD-06-A2-(-20-150)-M27-100/6-30A |
HOTLINE