中文版中文版MessageContact usSitemapWelcome toShanghai MX-CEKONG Technology Co.,Ltd website!
Hotline 400 662 6286

MX-CEKONG

Your position: HOME > Product > Flowmeter (116) >
Tel: 400 662 6286
  • Vortex Flowmeter MX-LL-116-02
Vortex Flowmeter MX-LL-116-02
Voetex Street Flowmeter (Shanghai) : The Voetex Street Flowmeter is researched and produced according to the Karman vortex street principle. It is mainly used for measuring the flow rate of medium fluids in industrial pipelines, such as gas, liquid, vapor and other media.It is characterized by small pressure loss, large range, high precision, and is almost unaffected by fluid density, pressure, temperature, viscosity and other parameters when measuring volume flow in working conditions.


Tel:

400 662 6286

1.Product description:  
      
Voetex Street Flowmeter (Shanghai) : The Voetex Street Flowmeter is researched and produced according to the Karman vortex street principle. It is mainly used for measuring the flow rate of medium fluids in industrial pipelines, such as gas, liquid, vapor and other media.It is characterized by small pressure loss, large range, high precision, and is almost unaffected by fluid density, pressure, temperature, viscosity and other parameters when measuring volume flow in working conditions.
_PL_1835 0.jpg
2.Applying field:  

1. Petrochemical industry, iron and steel metallurgy
2. Water supply and drainage, water conservancy irrigation
3. Water treatment, sewage treatment station
4. Mud, pulp, etc
5. Distillation and denitration engineering system
6. Paper-making (pulp), mud, medicine, food,etc.
7. Boiler, pipelines and other industrial field use

3.Feathers:

1. Integrated temperature pressure compensation function
2. Unimpeded flow measuring tube and the moving parts
3. High-definition backlit LCD display, easy to and operate
4. Simple structure and no moving mechanical parts
5. High precision, high reliability,

4.Installation tips and simple drawing:

5.Specifications:

Type description: MX-LL-116-02(no tem-pre compensation);MX-LL-116-02G(high-tem);MX-LL-116-02WY(tem-pre compensation);MX-LL-116-02DC(power supply.3.6V internal power supply); Inserted vortex flowmeter of MX-LL-116-02C type                                                      
Nominal diameter: DN15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、500、                                                     
Flow range: Reynolds number 1.5×104~4×106;gas 5~50m/s; liquid 0.5~7m/s                                                                    
Relative humidity: 5%-95%                                                            
Display form: LCD digital display                                                     
Precision description: Liquid precision:±1%(code name A2),precision of gas and steam:±1%(code name A2),±1.5%(code name A3)          (defaulted gas precision A3)                                                                                                                           
Medium tem: (-40~250)℃(code name W1);(-40~350)℃(W2);(-40~420)℃(W3)    
Environment tem: -20°~+60℃                                                     
Range ratio: 1:10(defaulted);1:15;1:20                                             
Atmospheric pressure 86KPA~106KPA                                                     
 
Pressure grade: P1 level40kg=4MPA;P2 level 16kg=1.6MPA;P3 level 25kg=2.5MPA   
Pressure loss: Drag coefficient cd≤2.4                                                                                                                                            
Supply form: 24VDC±5%(E1);Li-battery3.6VDC(E2)                                        
Signal output: S1=4-20MA two-wire(standard);S2=voltage frequency pulse signal,high level>6V,Generally8~10V ,low level 0.7~1.3V;S3=RS485 Communication interface;S4=HART Communication interface。    defaulted 4-20MA(optional)
Process connection: K1=Flange clamping connection type;K2=flange connection                                
Body material: flange connection defaulted stainless steel:304;316L(optional)

6.Selection guidance:

Type Path Precision Working tem Nominal diameter Power supply Signal output Process connection
MX-LL-116-02   DN50 1.5% -40~200 16kg 24VDC 4-20MA Flange connection
E g: MX-LL-116-02-DN50-A3-W1-P2-E1-S1-K2

7.Contact us:

Shanghai MX-CEKONG Technology Co.,Ltd

Email: 442365872@QQ.com
 
Tel: 021-67881626
 
Web: www.shmxck.com

Address: No. 488 Guanghua Road, Songjiang District, Shanghai